Samenwerking
voor de ontwikkeling van het elektronisch medisch
voorschrift
Recip-e:
Persbericht
Feitelijke vereniging Recip-e (april 2009)
Recip-e vzw opgericht:
Persbericht 29
januari 2010
|
Collaboration
pour le développement de la prescription médicale
électronique
Recip-e:
Communication de presse:
Association de fait: Recip-e
(avril 2009)
Recip-e asbl:
communiqué de presse 29 janvier 2010
|
|
|
|
|
27/01/2012 Optional release 0.7 of the modules:
Changelog: Improvement of the error messages.
Prescriber module
Executor module
|
27/01/2012 Optional release 0.7 of the modules:
Changelog: Improvement of the error messages.
Prescriber module
Executor module |
|
03/11/2011 New version Executor
V 0.6.1
Executor module |
03/11/2011 New version Executor V 0.6.1
Executor module |
28/10/2011: New version
integration modules V0.6
|
28/10/2011: New version
integration modules V0.6
|
24/05/2011: New version
integration modules V0.5
- Changes versus V0.4.0 :
- Minor Bug fixing (error management, etc)
- MyCarenet (Executor module only), more
information can be found in the integration
specifications
"*) The insurability orchestartion functionality is
for the moment only available on the integration
platform of eHealth (For development only). You will
receive new configuration update instruction when
the insurability orchestration functionality is
available on PreProd platform.
*) The direct connection is now available on the
PreProd platform. "
-
Recip-e Integration specification V 1. 8 0
Prescriber module
Executor module
|
24/05/2011: New version integration modules V0.5
- Changes versus V0.4.0 :
- Minor Bug fixing (error management, etc)
- MyCarenet (Executor module only), more
information can be found in the integration
specifications
"*) The insurability orchestartion functionality is
for the moment only available on the integration
platform of eHealth (For development only). You will
receive new configuration update instruction when
the insurability orchestration functionality is
available on PreProd platform.
*) The direct connection is now available on the
PreProd platform. "
-
Recip-e Integration specification V 1. 8 0
Prescriber module
Executor module
|
13/01/2011 New version of the
integration modules V0.4
- Changes compared to V0.3 :
- Version connected to PreProd Environment (Internal
Pilot)
- New E-Health test certificates included
- Bug Fixed :
o Login with EID for which name contains specific
characters
o Decryption of prescription created with
certificate no-longer valid
Prescriber module
Executor module
|
13/01/2011 New version of the
integration modules V0.4
- Changes compared to V0.3 :
- Version connected to PreProd Environment (Internal
Pilot)
- New E-Health test certificates included
- Bug Fixed :
o Login with EID for which name contains specific
characters
o Decryption of prescription created with
certificate no-longer valid
Prescriber module
Executor module |
1/12/2010 New version of the
integration modules V0.3.1
- Main changes (Recip-e
Integration Specification V 1.7 0:
- Fallback session enabled (without EID)
- Certificate Management simplified. Certificates
are configured with following parameters :
# The keypair of the system/application
KEYSTORE_FILE=%CONF%/p12/NIHII-PHARMACY=66666219_20101019-122059.p12
# The password of previous keypair
KEYSTORE_PASSWORD=pharmacy.
# The folder where should be stored the fallback
keypairs (personal certificates)
KEYSTORE_AUTH_P12_FOLDER=%CONF%/p12
Prescriber module
Executor module |
1/12/2010 New version of the
integration modules V0.3.1
- Main changes (Recip-e
Integration Specification V 1.7 0:
- Fallback session enabled (without EID)
- Certificate Management simplified. Certificates
are configured with following parameters :
# The keypair of the system/application
KEYSTORE_FILE=%CONF%/p12/NIHII-PHARMACY=66666219_20101019-122059.p12
# The password of previous keypair
KEYSTORE_PASSWORD=pharmacy.
# The folder where should be stored the fallback
keypairs (personal certificates)
KEYSTORE_AUTH_P12_FOLDER=%CONF%/p12
Prescriber module
Executor module
|
|
28/10/2010
Changes versus V0.2.0 :
-
Kmehr schema is upgraded to version
20100901. ("ns1" prefix is not required anymore)
-
Security enabled : the EID and the
Pin code are requested on CreateSession().
-
Application requires a system
certificate to communicate with the server :
-
Pharmacy : system certificate
is linked to the pharmacy (NIHII-PHARMACY). Test
certificates are included in the SDK.
-
Prescriber : system certificate
is linked to the responsible person of the software.
A test certificate is included in the SDK, Contact
us to get additional test certificate.
-
Personal certificates are required
for FallbackSession and must be added to the application
keystore. Follow this procedure to get a personal
certificate :
-
Use the ETEE requestor tool fase 1
to create an ehcsr. (http://wwwacc.ehealth.fgov.be/JWS/ETEE/etee-requestor_nl.jnlp)
=> Please fill in the correct contact information
(personal email and group email).
-
Send an e-mail to
acceptance-certificates@ehealth.fgov.be
This e-mail must contain the generated ehcsr in step 1
and also the additional NIHII number needed for
searching the ETK.
-
You will recieve an e-mail, using
the contact information in step 1 , from eHealth
(AccessCoordination) with in this e-mail the public key
and root CA.
-
Use the ETEE requestor tool fase 2
to generate and register the ETK's.
Note : the tool “keystore explorer” can be used to
maintain the keystore and define the passwords of each
private key.
-
Bug fixing :
-
NullPointerException on first
hasValidSession() invokation
-
XSD loading issue when path
contains spaces
-
Modules behind proxy
configuration
-
Sample : new Features :
Prescriber module
Executor module
Contact Point for technical questions :
Thibaut.henry@accenture.com |
28/10/2010 Changes versus
V0.2.0 :
-
Kmehr schema is upgraded to version
20100901. ("ns1" prefix is not required anymore)
-
Security enabled : the EID and the
Pin code are requested on CreateSession().
-
Application requires a system
certificate to communicate with the server :
-
Pharmacy : system certificate
is linked to the pharmacy (NIHII-PHARMACY). Test
certificates are included in the SDK.
-
Prescriber : system certificate
is linked to the responsible person of the software.
A test certificate is included in the SDK, Contact
us to get additional test certificate.
-
Personal certificates are required
for FallbackSession and must be added to the application
keystore. Follow this procedure to get a personal
certificate :
-
Use the ETEE requestor tool fase 1
to create an ehcsr. (http://wwwacc.ehealth.fgov.be/JWS/ETEE/etee-requestor_nl.jnlp)
=> Please fill in the correct contact information (personal
email and group email).
-
Send an e-mail to
acceptance-certificates@ehealth.fgov.be
This e-mail must contain the generated ehcsr in step 1
and also the additional NIHII number needed for
searching the ETK.
-
You will recieve an e-mail, using
the contact information in step 1 , from eHealth (AccessCoordination)
with in this e-mail the public key and root CA.
-
Use the ETEE requestor tool fase 2
to generate and register the ETK's.
Note : the tool “keystore explorer” can be used to
maintain the keystore and define the passwords of each
private key.
-
Bug fixing :
-
NullPointerException on first
hasValidSession() invokation
-
XSD loading issue when path
contains spaces
-
Modules behind proxy
configuration
-
Sample : new Features :
Prescriber module
Executor module
Contact Point for technical questions :
Thibaut.henry@accenture.com
|
|
28/09/2010:
Recip-e Integration Specification V 0.2
"Release note":
Module V0.2 : Main changes compared to V0.1 :
- Version connected to Recip-e central system.
- E-Health security is disabled (no eid required for
authentication, test certificate
included in the module).
- New API(s) for session Management: createFallbackSession(),
hasValidSession(), … (Refer
to spec for more information)
Prescriber module
Executor module
Version 0.3 will be published mid October including the full
security management of e-Health (EID + Certificates), no
change expected regarding the API. More information to be
followed.
|
28/09/2010
Recip-e Integration Specification V 0.2
"Release note":
Module V0.2 : Main changes compared to V0.1 :
- Version connected to Recip-e central system.
- E-Health security is disabled (no eid required for
authentication, test certificate
included in the module).
- New API(s) for session Management: createFallbackSession(),
hasValidSession(), … (Refer
to spec for more information)
Prescriber module
Executor module
Version 0.3 will be published mid October including the full
security management of e-Health (EID + Certificates), no
change expected regarding the API. More information to be
followed.
|
|
Recip-e / Integratiespecificatie
voor softwareontwikkelaars (23 aug 2010)
Dit (werk)document beschrijft een set van voorwaarden
voor de interface tussen het softwarepaket van de
voorschrijver (bv. huisarts) respectievelijk het
softwarepakket van de uitvoerder (bvb. apotheek, kinesist,
ambulant verpleegkundige) en het Recip-e systeem. Het
identificeert gevalideerde ontwerpvereisten en beperkingen
waaraan moet worden voldaan door de interfacingsoftware. Dit
document is bestemd voor ontwikkelaars van de bedoelde
toepassingen en voor de organisaties die verantwoordelijk
zijn voor de testen van deze toepassingen.
De huidige versies van de integratiemodules zijn uitsluitend
werkversies voor demonstratiedoeleinden en worden momenteel
nog aan de voorziene testprocedures onderworpen. Deze
versies kunnen bijgevolg nog worden aangepast. De
definitieve versies van de integratiemodules zullen te
gepasten tijde met vermelding van hun gevalideerde status
worden gepubliceerd.
Het eHealth-platform en de vzw Recip-e kunnen in geen geval
aansprakelijk worden gesteld voor elke vorm van schade,
direct of indirect, secundair of bijkomstig, materieel of
immaterieel, veroorzaakt door de gebruiker of derden,
voortkomend uit het gebruik van de werkversies of van de
gevalideerde versies van de integratiemodules, of uit de
onmogelijkheid om deze te gebruiken.
De respectieve integratiemodules zelf vindt u hierna:
|
Recipe-e / Spécifications
d’intégration pour les développeurs de logiciels (23 août
2010)
Ce document de travail décrit une série de conditions
pour l’interface entre le logiciel des prescripteurs (p.ex.
le généraliste), le logiciel des exécuteurs (p.ex. le
pharmacien, le kinesithérapeute ou l'infirmier) et le
système Recip-e. Il identifie les exigences et contraintes
de conception validées auxquelles le logiciel d’interfaçage
doit satisfaire. Ce document est destiné aux développeurs
des applications visées et aux organisations responsables de
tester ces applications. Les versions actuelles des modules
d’intégration ne sont que des versions de travail à titre de
démonstration qui font, à l’heure actuelle, l’objet des
procédures de test. Ces versions peuvent donc encore être
adaptées. Les versions définitives des modules d’intégration
seront publiées en temps utile, avec mention de leur statut
validé.
La plate-forme eHealth et l’asbl Recip-e ne peuvent, en
aucun cas, être tenues pour responsables de tout dommage,
direct ou indirect, secondaire ou accessoire, matériel ou
moral, causé par l’utilisateur ou par des tiers, découlant
de l’utilisation des versions de travail ou des versions
validées des modules d’intégration ou de l’impossibilité
d'utiliser celles-ci.
Vous trouvez les modules d'intégration respectifs ci-après:
|